FEM Température initiale

From FreeCAD Documentation
Revision as of 12:43, 4 August 2018 by FuzzyBot (talk | contribs) (Updating to match new version of source page)

FEM ConstraintInitialTemperature

Emplacement du menu
Model → Thermal Constraints → Constraint initial temperature
Ateliers
FEM
Raccourci par défaut
Aucun
Introduit dans la version
-
Voir aussi
FEM tutorial

Description

Creates an initial temperature constraint for a thermo-mechanical analysis.

Use

  1. Click on or choose ModelThermal Constraints Constraint initial temperature from the top menu.
  2. Enter an initial temperature value for the analysis.

Limitations

The constraint applies the initial temperature to all nodes in the FEA model

Notes

  1. The constraint uses the **INITIAL CONDITIONS card in CalculiX. The initial temperature constraint is explained at http://web.mit.edu/calculix_v2.7/CalculiX/ccx_2.7/doc/ccx/node215.html