FEM ConstraintFlowVelocity/ru: Difference between revisions

From FreeCAD Documentation
(Created page with "==Описание==")
(Created page with "Устанавливает скорость потока в качестве граничного условия к кромке в 2D или к грани в 3D.")
Line 21: Line 21:
==Описание==
==Описание==


Устанавливает скорость потока в качестве граничного условия к кромке в 2D или к грани в 3D.
Applies a flow velocity as boundary condition to an edge in 2D or to a face in 3D.


==Usage==
==Usage==

Revision as of 19:02, 27 November 2020

Other languages:

FEM ConstraintFlowVelocity

Системное название
FEM ConstraintFlowVelocity
Расположение в меню
Model → Fluid constraints → Constraint flow velocity
Верстаки
FEM
Быстрые клавиши
Нет
Представлено в версии
-
См. также
FEM tutorial

Описание

Устанавливает скорость потока в качестве граничного условия к кромке в 2D или к грани в 3D.

Usage

  1. Click on or choose Model → Fluid Constraints → Constraint flow velocity from the top menu.
  2. The task panel will display menus for constraint flow velocity

    Above: Constraint flow velocity menus within the task panel

  3. Select the target Edges or Faces.
  4. Click Add
  5. Deselect "unspecified" to activate the necessary fields for edition.
  6. Fill in the values in mm/s for the main Cartesian components.

Notes

  • Vector components that are ticked as "unspecified" will be interpolated by the selected solver.
    Any vector that should be the result of the solver must be ticked as "unspecified".
  • If the target face or edge is not aligned with the main cartesian coordinate system, it is possible to tick "normal to boundary".
    If "normal to boundary" is ticked, the normal vector to the selected edge or face is X and it will be oriented away from the mesh domain.
    For example, if a flow of 20 mm/s of air must enter the domain, then after ticking "normal to boundary" the user will have to input -20 mm/s in the "velocity X" field.
  • For a Wall with non-slip condition, the flow will be (0,0,0)
  • For a Symmetry condition, the flow will be (0, Unspecified, Unspecified) if "normal to boundary" is ticked.