<!--T:7-->
<!--T:7-->
# Either press the {{Button|[[Image:FEM_ConstraintBodyHeatSource.svg|16px]] '''FEM_ConstraintBodyHeatSource'''}} or select the menu {{MenuCommand|Model → Thermal Constraints → [[Image:FEM_ConstraintBodyHeatSource.svg|16px]] Constraint body heat source}}.
# There are several ways to invoke the command:
# Set the value:
#* Press the {{Button|[[Image:FEM_ConstraintBodyHeatSource.svg|16px]] [[FEM_ConstraintBodyHeatSource|FEM ConstraintBodyHeatSource]]}} button.
#* {{VersionPlus|1.0}}: For a 3D analysis, select a 'solid' (body) from your model, for a 2D analysis select a face.
#* Select the {{MenuCommand|Model → Thermal Constraints → [[Image:FEM_ConstraintBodyHeatSource.svg|16px]] Constraint body heat source}} option from the menu.
# Since the constraint does not yet has a task dialog, use the [[Property_editor|property editor]] to set</br>{{PropertyData|Heat Source}}.
#* {{VersionMinus|0.20}} Since the constraint has no task dialog, use the [[Property_editor|property editor]] and set the property {{PropertyData|Heat Source}}.


==Limitations==
==Limitations==

Revision as of 01:16, 15 August 2022

FEM ConstraintBodyHeatSource

Menu location
Model → Thermal Constraints → Constraint body heat source
Workbenches
FEM
Default shortcut
None
Introduced in version
0.19
See also
FEM tutorial

Description

Defines an internally generated body heat given in W/kg.

Usage

  1. Either press the FEM_ConstraintBodyHeatSource or select the menu Model → Thermal Constraints → Constraint body heat source.
  2. Set the value:
    • version 1.0 and above: For a 3D analysis, select a 'solid' (body) from your model, for a 2D analysis select a face.
    • version 0.20 and below Since the constraint has no task dialog, use the property editor and set the property DataHeat Source.

Limitations

  • This constraint works only with the Elmer solver, it has no effect when CalculiX is used as a solver.
  • Body heat source is applied to the whole model, it's not possible to select individual regions.